GENERAL INFORMATION
Inspection Address
Street: 1234 Sample Ave.
City: Vancouver
State: BC
Zip: 12345
Inspection Details
Inspection Date: Monday 12,June 2006
Report Delivered: by web site download
Weather Conditions: sunny
Temperature: 60
Present During Inspection: buyerbuyer's agent
Occupied: yes occupied
Construction Type
Construction Style: residence is a two story
Structure Type: detached
Construction Material: wood frame
Residence Type: single-family dwelling
Bedrooms: three
Bathrooms: one and a half
Kitchens: one
Supporting Foundation: includes a basement
Building Details
Date Built: 1926
Approximate Area: 2490 sq. ft.
Entrance Faces: south
Nearest Fire Hydrant: within 500 yards
Client Information
Name: Mr. Smart
Address: 123 Sample Rd.
City: Victoria
State: Arizona
Zip: 123456
Home: 123 456 7890
Email: mrsmart@smart.org
Inspected By
Name: Joe Inspector
License: NACHI, ASHI
Company Information
Company: Joe's Inspections
Address: 1876 Main St
City: Victoria
State: BC
Zip: 99876
Phone: (250) 887-9987
Cell: (250) 887-cell
Pager: (250) 887-page
FAX: (250) 887-1fax
Email: info@inspectexpress.com
Web Site: www.inspectexpress.com
EXTERIOR
In accordance with the ASHI© standard of practice pertaining to Exteriors, this report describes the exterior wall coverings and trim. Inspectors are required to inspect the exterior wall coverings, flashing, trim, all exterior doors, the stoops, steps porches and their associated railings, any attached decks and balconies and eaves, soffits and fascias accessible from ground level.
Building Exterior
Wall Surface Material: and portland cement stucco
Condition: good condition
Wall Trim: and aluminum
Condition: good condition
Entry Door Types: and solid wood
Condition: good condition
Garage Door: wood panel, sectional rollup
Condition: routine maintenance needed
Eave Type: closed cornices with no overhang and no vents
Condition: satisfactory condition
Sun Deck - Patio
Sun Deck Type: vinyl composite lumber
Sun Deck Location: in the back
Condition: good condition
Deck Porch Railing: wood with latticed balusters
Condition: good condition
Deck Support: wooden support columns
Condition: servicing recommended
Foundation
Foundation Type: and a combination basement-slab
Foundation Material: and reinforced concrete
Slope and Drainage
Direction of Lot Slope: slopes away from the home on all sides
Condition: adequate
Drainage Piping: concrete
Drains Connected to: municipal
Gutters Downspouts Drain: perimeter
Downspouts Empty into: storm drains
Drives Walks and Patios
Driveway Types: and asphalt
Condition: requires maintenance
Walkway Type: and concrete
Condition: good condition
Flatwork Type: and concrete
Flatwork Locations: in the backalong the side
Condition: good condition
Contact between the exterior wall surface and grade was noted at some points along the perimeter of the residence. This state promotes a condition that is conducive to infestation by wood deteriorating organisms or wood rot. It is important that materials such as leaves, vegetation, soil, silt or other debris are not permitted to accumulate at any part of the lower exterior wall. Recommendation: Adjust grade to provide for a 4-inch separation between the bottom of the wall and grade.
The stucco cladding is stained. I don't know what caused the staining and recommend cleaning the stucco. If cleaning doesn't remove the stains, it may be necessary to paint the affected area. I don't recommend that the client attempt to do this as a do-it-yourselfer project, since only paint specifically formulated for stucco should be used for this purpose. Consult a reputable stucco contractor to discuss options and cost.
There is contact between the exterior cladding and grade. This kind of contact can cause moisture damage to cladding, underlying sheathing and framing, or result in insect infestation. There needs to be at least six inches of clearance between siding components and grade, and leaves, vegetation or other debris should not accumulate against any part of the exterior. I recommend correcting this right away. .jpg)
There is loose, damaged or missing trim. Besides being unsightly, loose/missing trim can result in water penetration that leads to rot and insect infestation. A competent carpenter needs to make repairs.
A weather-exposed entry door is leaking around the threshold into the interior and will need to be repaired. Besides damage to finished flooring or floor coverings, water infiltration into the sub-floor and framing beneath an entrance can eventually lead to rot or insect infestation. When an exterior door is exposed to the weather as this one is, the area beneath the threshold needs to be thoroughly and carefully flashed. Many builders install custom drain pans that the door and casing rest in and which drain to the exterior. Since I am seeing leakage into the interior, it is obvious that no such flashing or pan has been installed. I recommend immediate correction by a competent carpenter or door/window professional.
Inspectors are NOT required to inspect or report on the presence or condition of recreational facilities, outbuildings, seawalls, break-walls and docks, window and door screening, shutters, awnings or similar seasonal accessories.
ROOF SYSTEM
In accordance with the ASHI© standard of practice pertaining to Roof Systems, this report describes the roof coverings and the method used to inspect the roof. Inspectors are required to inspect the roof covering, roof drainage systems, flashings, skylights, chimneys and roof penetrations.
Roof Covering
Roof Inspected: by walking the entire surface
Roof Slope: has a low slope
Roof Style: and hip with cross gables style
Roofing Materials: and asphalt shingles
Material Condition: in excellent condition
Flashing
Flashing Type: and galvanized steel
Flashing Locations: roof valleysbase of the chimney(s)
Gutters Downspouts
Gutter Downspout Type: and plastic
Gutters Downspouts Drain: spill out onto grade
Skylights
Skylight Type: and fixed-lens, glass, curbless
Skylight Locations: on the front slopeon the rear slope
Chimneys
Chimneys Type: one masonry stack, single flue-fireplace
Fireplace Stove Locations: family roomdaylight basement
There is either no or incomplete/incorrect drip edging installed around the perimeter of this roof. Both the National Roofing Contractors Association (NRCA) and the Asphalt Roofing Manufacturers Association (ARMA) recommend drip edging are installed at the rakes and eaves of all roofs. This is to limit exposure of the edges of the roof decking to wind-driven rain, capillary action or splash back from gutters that could eventually lead to failure of the roof decking. These instructions are clearly spelled out in the installation manuals of both of these organizations. While it might be the case that few roofers in this particular region customarily install drip edging, I feel that, if NRCA and ARMA see it as a necessary component of the roof system, it should not be omitted and correction by a reputable roofer is recommended.
Some damaged or missing roof shingles were noted. Immediate repair by a reputable roofing contractor is recommended. .jpg)
The flashings are rusting and will need to be serviced by cleaning, priming and painting with a rust-inhibitive finish. Any experienced handyperson should be able to accomplish this without any difficulty.
.jpg)
Inspectors are NOT required to inspect antennae, interiors of chimneys or flues that are not readily accessible or other installed accessory items.
ELECTRICAL SYSTEM
In accordance with the ASHI© standard of practice pertaining to Electrical Systems, this report describes the amperage and voltage rating of the service, the location of the main disconnect and any sub panel(s), the presence of solid conductor aluminum branch circuit wiring and the absence of smoke detectors. Inspectors are required to inspect the viewable portions of the service drop from the utility to the house, the service entrance conductors, cables and raceways, the service equipment and main disconnects, the service grounding, the interior components of the service panels and sub panels, the conductors, the over-current protection devices (fuses or breakers), ground fault circuit interrupters and a representative number of installed lighting fixtures, switches and receptacles.
Service Entry
Service Drop Type: overhead solid 3-wire
Condition: good condition
Service Entry Conductor: copper
Condition: good condition
Main Disconnect
Main Disconnect Type: breaker
Main Disconnect Rating: 200 amps
Main Disconnect Location: outside at the front of the residence
Main Panel
Service Entrance Panel Location: inside of the building
Panel Type: General Electric
Panel Style: breaker system
Amperage Rating: 200 amps
Voltage Rating: 115/230 volts
Condition: not inspected - power off
Room in service panel: Panel Full
Distribution Wiring
Wiring Type: and non-metallic sheathed cable (romex)
Wiring Conductors: copper
Condition: acceptable condition
Sub Panel
Sub Panel Location: garage
Sub Panel Type: General Electric
Sub Panel Style: breaker system
Sub Panel Amperage Rating: 60 amp
Sub Panel Voltage Rating: 115/230 volt
Condition: servicing recommended
Outlets
Outlets & Switches Tested: basement, garage and kitchen
Smoke Alarms
Smoke Alarms: Battery Powered
Alarms Tested: Working Okay
Carbon Monoxide Detector: None Found
GFCI
Ground Fault Circuit Interruptors: Found
Installed GFCI Locations: kitchenmain bathroom
Missing GFCI Locations: and laundry room
AFCI
Arc Fault Circuit Interruptors: Found
Installed AFCI Locations: and laundry room
The service drop is poorly anchored to the house and in danger of being pulled loose. If it pulls loose the strain on the drop could loosen or detach the neutral cable, causing the household voltage to be unstable. Essentially all circuits in the home could become 240volt circuits, burning out some appliances or convenience items and posing a substantial hazard. I recommend having the drop attachment immediately repaired by the utility provider.
I found what appeared to be illegal taps or splices installed on the electrical system that bypass the meter. I recommend this be investigated and corrected as necessary by a reputable electrician or the utility provider.
There is no circuit identifying legend on the interior panel cover in the electrical service box as required. Recommendation: Identify circuits and create a proper legend on the interior panel as required.
Because of the way it wobbles, I believe that the driven grounding electrode is too short and may have been cut short. Grounding electrodes are typically 8ft. long and must be driven their full length into the ground. Sometimes, when this is difficult, an electrician will cut a rod short, in which case there may be too little rod surface in contact with earth to provide an adequate ground. I recommend that a licensed electrician investigate this further and make corrections as needed.
.jpg)
Inspectors are NOT required to inspect any remote control devices (unless such device is the only means of control), alarm systems and associated components and controls, low-voltage wiring systems or components or any ancillary wiring, systems or components that are not part of the primary power distribution system. We are also NOT required to measure amperage draw, line voltage or ground impedance.
HEATING SYSTEM
In accordance with the ASHI© standard of practice pertaining to Heating Systems, this report describes the energy source and the distinguishing characteristics of the heating system(s). Inspectors are required to inspect the installed heating equipment and associated vent systems, flues and chimneys.
Heating Systems
Type of Heating System: and a forced air oil furnace
Heating System Location: basement utility room
Condition: started as expected using normal controls
Location Electric Safety Switch: at the furnace/boiler unit
Type of Thermostats: programmable
Location of Thermostats: main floor hallliving room
Condition: started as expected using normal controls
Furnace
Make: TEST
Model: TEST
Serial Number: 1234578910
Last Service Date: 1998
Exhaust
Exhaust Vent Type: single-wall metal
Exhausts Through: exhausts into an unlined masonry chimney
Condition: satisfactory condition
Flue Shared with Hot Water: yes
System Started as Expected: yes
Inspection Tag Present: NO
Meets Rough Heating Calc.: yes
Oil System
Tank Above or Below Ground: belowground
Location of Tank: at the rear
Condition of Tank: in-service unknown/unviewable
Exterior Fuel Cutoff Location: at the top of the oil tank
Fuel Line Plumbing: flexible copper tubing
Interior Fuel Cutoff Location: the furnace room
Ducting Ventilation
Type of Ducting: galvanized sheetmetal
Condition: needs cleaning
Type of Return Ducting: galvanized steel sheetmetal
Air Filter
Location: return before furnace
Type: fiberglass cartridge
Condition: in need of replacement
The furnace/boiler housing is badly rusted. This usually indicates exhaust condensate leakage, a backdrafting flue or, in the case of a hot water/steam system, may indicate a boiler leak. I recommend having this unit immediately inspected and repaired as necessary by a reputable/professional HVAC firm.
The flexible connector used between the rigid gas line and the furnace/boiler control valve is the wrong type or is not approved for this region. I recommend immediate replacement by a licensed pipe fitter.
I noted obvious acidic deterioration of furnace/boiler components. This is typically caused by severe backdrafting, a blocked flue or a condensate leak. Further investigation and repair by a reputable/professional HVAC firm is recommended.
Oil stains were noted on the floor at the oil furnace/boiler. Indicating a possible leak. As this is a potential fire hazard, it should be immediately referred to a reputable/professional HVAC firm for correction as appropriate.
Based on the age of the system and the appearance of the material, I believe the material used to wrap/seal the heating ducts has a high probability of containing asbestos fiber, a health hazard. The material doesn't appear to have been damaged and I don't recommend tampering with it, unless it is tested and found to not contain asbestos.
Unless it is damaged to the point where fibers are friable (breaking off into the air and can be breathed), there is little risk of harm from this material. However, it can be made safer by having it encapsulated in latex heating duct mastic. If remediation is desired, I recommend using only a properly trained and EPA licensed asbestos abatement contractor.
Inspectors are NOT required to inspect the interiors of flues or chimneys when not readily accessible, the heat exchanger(s) of boilers or furnaces, humidifiers or dehumidifiers, electronic air cleaners or any solar space heating system(s). We are also NOT required to determine the adequacy of the heating system or distribution/balance of heat throughout the home.
PLUMBING SYSTEM
In accordance with the ASHI © standard of practice pertaining to Plumbing Systems, this report describes the water supply, drain, waste and vent piping materials and the water heating equipment, energy source and location of the main water and main fuel shut-off valves, when readily viewable or known. Inspectors are required to inspect the interior water supply and distribution systems, all fixtures and faucets, the drain waste and vent systems (including all fixtures for conveying waste), the water heating equipment (vent systems, flues and chimneys of water heaters or boiler equipment), fuel storage and distributions systems for water heaters and/or boiler equipment and drainage sumps, sump pumps and associated piping.
Supply and Piping
Supply and Waste System: a municipal supply and waste system
Service Piping Size: and 3/4-inch
Service Piping Type: and ABS plastic
Branch Piping Size: 1/2-inch3/4-inch
Branch Piping Type: and copper
Condition: satisfactory condition
Fixtures/Faucets Condition: adequate
Supports/Insulation Condition: satisfactory condition
Functional Flow: adequate
Function Drainage: adequate
Waste Piping: and PVC DWV plastic
Condition: good condition
Main Water Shut Off Location: under the basement stairs
Main Water Regulator Location: under the basement stairs
Water Heater
Water Heater Type: and a conventional storage tank
Water Heater Energy Source: and oil
Capacity: 80 Gallons
Water Heater Location: and under the basement stairs
Water Heater Vented: into a lined masonry chimney
Fuel Tank and Controls
Fuel Shut Off Location: at the hot water tank
Automatic Safety Controls (TPR) Condition: tested - functional
Sump Pump
Tested: operational condition
I noted mineral deposits/rust staining at pipe elbows that indicate possible leakage or weak pipe walls that will need further investigation and correction as necessary.
I noted signs of previous plumbing leaks (water-damaged floors, cabinet bottoms, stains at walls, etc.) that may be indicative of recent repairs to the system. If this hadn't been previously disclosed, I recommend the client determine from the homeowner exactly what those repairs had been.
The toilet in the @@@ bath has a very weak flush and may be prone to clogging. This could simply be a design flaw with this particular toilet or the holes at the bowl rim may be occluded with lime and need to be cleaned out. This will require further investigation and correction as appropriate.
I tested the water pressure using a gauge and found it to be less than 15 lbs. static pressure. This is below minimum standards for everyday usage and should be corrected. This may require the addition of an auxiliary booster pump or pressure tank in order to achieve acceptable levels.
All of the supply water, whether hot or cold, is brown with rust when drawn. This normally indicates the minor rusting that takes place inside galvanized pipe when the water hasn't been run for several days. Such minor rust will normally flush out of the system within 20 - 40 seconds of the tap being opened. However, I ran the water for some minutes, in order to flush the residue out of the plumbing, and was unsuccessful in eliminating the color. I suspect this has been caused by badly rusted pipes or is entering the supply plumbing from the water supply. If it originates in the pipes of this house, deterioration that is this bad could necessitate near-term, if not immediate, replacement of the affected plumbing. This will require further assessment to determine the exact cause of the rust and to correct it.
Inspectors are NOT required to inspect the connections for clothes washing machines, interiors of flues or chimneys when not readily accessible, wells or well pumps, equipment associated with water storage, water conditioning equipment, solar water heating components or systems, fire sprinkler or irrigation systems or private waste disposal (septic) systems. Additionally, inspectors are not required to operate safety valves or shut-off valves of any kind. We DO NOT determine the quantity or quality of water supplies or whether water supply and waste disposal systems are public or private.
INTERIOR
In accordance with the ASHI© standard of practice pertaining to Interiors, there is NO requirement for the report to describe any interior components or finishes. Inspectors are required to inspect walls, ceilings and floors, steps, stairways and railings, countertops and a representative number of cabinets, a representative number of doors and windows and the garage doors and automatic garage operators.
Room Interior
Wall Surface Type: and sheetrock
Condition: satisfactory condition
Ceiling Surface Type: and sheetrock
Condition: satisfactory condition
Flooring Type: and carpeting throughout
Condition: acceptable condition
Kitchen Flooring Material: sheet vinyl
Condition: in need of replacement
Kitchen Counter Top Type: plastic laminate
Condition: adequate
Cabinets and Counters
Kitchen Cabinet Type: composition board
Condition: good condition
Bathroom Flooring Material: and sheet vinyl
Condition: satisfactory condition
Bathroom Counter Top Type: plastic laminate
Condition: good condition
Bathroom Cabinet Type: composition board
Condition: satisfactory condition
Inside Door Type: solid woodhollow core wood panel
Condition: routine maintenance needed
Windows and Doors
Window Frame Type: and wood
Window Pane Type: and single glazed
Condition: not adequate
Garage Door
Garage Door Type: wood panel, sectional rollup
Condition: did not function using normal controls - servicing needed
Garage Doors Opener: Automatic
Garage Walk Through Door: meets code
Garage Walk Through Door Condition: satisfactory condition
Fire Separation Walls and Ceilings Condition: no access - not inspected
Small carpet stains are visible at random areas of the home.
There are minor wall blemishes throughout the home that are of no real significance to this inspection. I only report on individual conditions that are significant and that indicate underlying defects of a more serious nature, such as settling, structural inadequacies, water intrusion, rot or insect damage.
There is damaged/missing door trim around one or more doors in the home that needs to be repaired by a competent trim carpenter.
The resilient floor tiles are heavily worn and long overdue for replacement. Consult a reputable floor-covering firm to discuss replacement options and cost.
There are one or more cabinets in the @@@ with loose/broken hinges.
The edges of the resilient surfaces at the kitchen counters are lifting. The material will need to be re-adhered by a professional cabinetmaker.
Inspectors are NOT required to inspect paint, wallpaper or other finish treatments, carpeting, window treatments, central vacuum systems, household appliances and recreational facilities or gymnastic equipment.
INSULATION AND VENTILATION
In accordance with the ASHI© standard of practice pertaining to Insulation and Ventilation Systems, this report describes the insulation and vapor retarders used in unfinished spaces when readily accessible and the absence of insulation in unfinished spaces at conditioned surfaces. Inspectors are required to inspect insulation and vapor retarders in unfinished spaces when accessible, ventilation of attics and foundation (crawlspace) areas and mechanical ventilation systems, if present.
Attic Locations and Access
Attic Spaces: one
Attic Access Locations: and hallway
Certificate Posted: attic
Certificate Insulation Locations: attic only
Attic Floor Insulation
Insulation Type: fiberglass batt
Insulation Measure: 6 inches
Insulation R-Value: 20
Vapor Retarder: polyethylene plastic
Wall Insulation
Insulation Type: unknown old house
Crawlspace Insulation
Insulated: joist bays only
Insulation Type: and fiberglass batt
Insulation Measure: 4 inches
Floor Insulation R-Value: 20
Under floor Barrier: none
Crawlspace Barrier: none
Attic Ventilation
Attic Ventilation Type: passive ventilation
Attic Ventilation Intake Location: undereave vents
Attic Exhaust Ventilation: roof vents
House Ventilation
Exhaust Fans Devices: bathrooms only
Whole House Vent System: whole house fan(ceiling type-old)
There is no seal at the attic access hatch. This will result in some loss of energy as heated air from the home leaks into the attic space(s). It is recommended that the hatch be fitted with a tight-fitting seal.
Signs of vermin-trails through/over the insulation, droppings, urine spots and nesting materials - were found in this attic. This may or may not be a condition that has already been resolved. It is recommended that further inspection be done by a licensed pest control operator/exterminator and remediation as necessary.
One or more exhaust vents in the attic have been fully utilized or partially blocked by ducting for source specific exhaust fans. This is an incorrect installation that compromises the ventilation of the attic space. All exhaust device manufacturers specify that their product be connected to dedicated through-the-roof rain caps that ensure that 100% of all moisture-laden air is exhausted to the outside. Simply stuffing a duct up into the bonnet of a roof vent doesn't meet this requirement. In fact, by cutting down on the available draft at one or more exhaust vents, this compromises attic ventilation. It is recommended that separate, dedicated through-the-roof rain caps be installed for as close to the fan source as possible using insulated ducting. This will minimize the possibility of condensation taking place inside the ducts and eventually leaking to the home below. Any competent carpenter or experienced handyperson can install a dedicated rain cap in about an hour.
The walls of the home have been filled with vermiculite mineral insulation. This product has been used in hundreds of thousands of homes throughout the US and Canada, with the most popular brand being a W.R. Grace product known as Zonolite. While vermiculite has been shown to be a very good insulator, research has shown that it often contains harmful asbestos fibers, and lawsuits are pending wherein workers exposed to it on a regular basis have developed respiratory illnesses and cancer. At present, there are a number of class-action lawsuits pending involving the product. Although environmental testing is outside the scope of this inspection, it is important for client(s) to understand that the presence of this product in a home may pose some degree of risk that asbestos fibers could be released into the air if the product is disturbed during repairs, remodeling or renovations. There are environmental testing firms that can sample the material to determine if it does in fact contain asbestos. Similarly, licensed asbestos remediation firms may be able to remove or encapsulate the product. It is recommended as additional due diligence that the client(s) consult such firms in order to gauge their level of risk.
Heating ducts and water piping routed through the unheated crawlspace will undoubtedly result in energy lost as the hot air in the ducts and hot water in the pipes has its temperature lowered. Under such conditions it is recommended that the ductwork and piping be insulated. Any reputable heating contractor, or even an experienced handyperson, can insulate these components in about a day.
The master bath exhaust fan is inoperative. Repair or replacement is recommended.
Inspectors are NOT required to determine indoor air quality or disturb insulation or vapor retarders, unless required by law.
STRUCTURAL SYSTEM
In accordance with the ASHI© standard of practice pertaining to Structural Systems, this report describes the foundation, floor, wall, ceiling and roof structures and the method used to inspect any accessible attics and under floor crawlspace areas. Inspectors are required to inspect and probe the structural components of the home, including the foundation and framing, where deterioration is suspected or where clear indications of possible deterioration exist.
Construction Type
Structure Type: residence is a one story
Attached - Detached: detached
Building Foundation
Foundation Type: and basement
Foundation Material: and poured concrete
Structural movement: Normal Settlement - Minor Cracking
Support Columns: wooden support
Condition: satisfactory condition
Wall Structure
Wall Studs: 2 by 4
Wall On-Center: 16-inch
Wall Sheathing: particle board sheathing
Floor Structure
Floor Framing: platform framing
Floor Joists: 2 by 10 joists
Floor On-Center: 16-inch
Floor Sheathing: T & G particle board sheathing
Roof Structure
Roof Assembly Type: wood frame assembly
Rafter Support: 2 by 10
Rafter/Support On-Center: 16-inch
Roof Sheathing: spaced sheathing
Ceiling Joist: 2 by 10
Ceiling Joist On-Center: 16-inch
Condition: satisfactory condition
Attic Entrance Inspection
Inspection Method: flashlight
Entrance Location: in the hallway
The exterior of the foundation footing is exposed. This leaves the foundation vulnerable to frost heave as well as to rain or surface drainage that can undermine the footings. Footers should not be exposed and should go at least to below frost depth, unless specifically designed as part of a frost-protected type of foundation. The foundation needs to be buried to an appropriate depth to properly protect these footings. Recommendation: Evaluation by a structural engineer and repair as appropriate.
One or more posts that support the main structure, additions, exterior decks and/or stairs is buried in soil and is rotting. If not corrected, this could eventually lead to pest infestation and even structural damage to the home. Even pressure-treated posts and those encased in concrete footings need to be kept free of soil to limit saturation and exposure to rot and insects. Recommendation: Adjust the height of grading around all of the support posts to ensure at least four inches of clearance from the soil. All rot or insect-damaged posts should be repaired or replaced.
No foundation anchors were observed in any crawlspace or basement. They may have been accidentally omitted or are concealed inside walls. It's also possible that the home was never intended to have them, since the use of sill-to-foundation anchors is a relatively recent phenomenon and many homes built prior to the 1940's didn't have them. Determining this for certain will probably require invasive inspection and is outside the scope of this inspection. Recommendation: Further evaluation and retrofit of anchors, if necessary, by a licensed contractor.
Some of the heating ductwork in the crawlspace is loose, leaking, improperly suspended or has been disconnected. Recommendation: Repair as appropriate by a licensed HVAC contractor.
There appeared to be mold or mildew coating the surface of some of the under floor components in the crawlspace. Mold needs moisture to thrive, however, no evidence of a plumbing or infiltration leak was observed.
Some types of mold organisms are supposed to be toxic to humans. Determining whether the material observed poses a health risk is outside the scope of this inspection.
If desired, an indoor air quality (IAQ) firm specializing in mold identification and abatement can examine the substance, to determine exactly what it is and whether any of the substance has spread to the living spaces above.
The vapor barrier in the crawlspace is inadequate, as it doesn't cover 100% of the soil under the home or has been rendered ineffective by damage. This is important because the barrier limits the amount of moisture that can evaporate out of the soil into the crawlspace. High humidity can result in mold and rot that lead to infestation by wood-destroying insects and eventually structural damage. Recommendation: Evaluation and repair by a licensed insulation contractor.
I found indications of wood-destroying insect infestation in the home. Infestation by wood-destroying insects is normally a symptom of high moisture levels in wood that have caused the wood to rot or soften enough to make tunneling by insects possible. If I saw a water intrusion issue that contributed to this, it has been documented elsewhere in this report. Otherwise, I don't know what led to this infestation. Regardless, I recommend a follow-up inspection by a licensed pest control operator (PCO) to identify the insects involved, determine the exact cause of infestation and the extent of damage to the home, prescribe repairs and treat the home as necessary to eliminate the infestation and provide residual protection. Thereafter, I recommend follow-up inspections and treatments a necessary at two to three year intervals.
Probing is not done when doing so will damage finished surfaces, when no visible deterioration exists and if doing so requires inspectors to be licensed pest control operators (PCO), unless the inspector involved is so licensed. Inspectors are NOT required to offer an opinion as to the structural adequacy of any structural systems or components or provide architectural services or an engineering or structural analysis of any kind.

Yours truly,
|