| 4.1 | Components for Inspection. | ||
| 4.1.1 | Foundation walls, first-floor systems, other support and sub-structure components, stairs. | ||
| 4.1.2 | Ventilation (when applicable). | ||
| 4.1.3 | Grade slab and/or floor slab. | ||
| |
|||
| 4.2 | Procedures for Inspection. | ||
| The Inspector will: |
|||
| 4.2.1 | Identify the type of structure and material comprising the structure and other items inspected. | ||
| 4.2.2 | Observe the condition and serviceability of visible, exposed areas of foundation walls, grade slab, bearing walls, posts, piers, beams, joists, trusses, subfloors, chimney foundations, stairs, and other similar structural components. | ||
| 4.2.3 | Inspect foundations for indications of flooding, moisture, or water penetration. | ||
| 4.2.4 | Observe subfloor crawl space ventilation and vapor barriers. | ||
| 4.2.5 | Operate the sump pump when present. | ||
| 4.2.6 | Inspect the visible and accessible wooden members. | ||
| 4.2.7 | Observe the visible condition of floor slab when present. | ||
| |
|||
| 4.3 | Limitations. | ||
The Inspector is not required to: |
|||
| 4.3.1 | Enter subfloor crawl spaces with headroom of less than 3 feet, obstructions, or other detrimental conditions. | ||
| 4.3.2 | Move stored items or debris or perform excavation to gain access. | ||
| 4.3.3 | Enter areas which, in the inspector's opinion, may contain conditions or materials hazardous to the health and safety of the Inspector. | ||
| 4.3.4 | Operate sump pumps equipped with internal/water dependent switches. | ||
| Back to Top | Go Back |
| Updated: 07-May-2003 | copyright NAHI - reprinted by permission |